GFCB main circuit breaker. BR ground fault self-test. Interrupt rating 10 kAIC. Common trip. 2-pole, requires two 1 in spaces. 120/240 V. Meets Federal Spec Classification W-C375...
Standard meter center, all-in-one, 1 in BR branch breaker type, EUSERC, 25 KAIC, 12/24 distribution, BR2100 main breaker included. Bottom and top feed, ring style, UG/UG service. Rainproof enclosure. 5-3/8 in D x 14-7/16 in W x 23-7/8 in H...
Standard meter center, all-in-one, 1 in BR branch breaker type, EUSERC, 25 KAIC, 12/24 distribution, BR2100 main breaker included. Bottom and top feed, ring style, UG/UG service. Rainproof enclosure. 5-3/8 in D x 14-7/16 in W x 23-7/8 in H...
All-In-One, BR branch breaker type, EUSERC, 25 KAIC, 20/40 distribution, BW2200 main breaker included. Bottom and top feed, ring style, UG/OH service. 5-3/8 in D x 14-7/16 in W x 43-3/8 in H...
A meter breaker is service entrance equipment that consists of a single meter socket and load center (circuit breaker distribution section) or meter socket and main breaker combined in one enclosure. Sometimes called combos, all-in-ones, meter centers or meter mains these units are increasing in pop..
All-in-one, BR branch breaker type, EUSERC, 25 KAIC, 40 distribution, 4-jaw, BW2200 main breaker included. Bottom and top feed, ring style, UG/OH service. 5-3/8 in D x 14-7/16 in W x 34-3/8 in H...
A meter breaker is service entrance equipment that consists of a single meter socket and load center (circuit breaker distribution section) or meter socket and main breaker combined in one enclosure. Sometimes called combos, all-in-ones, meter centers or meter mains these units are increasing in pop..
Single meter socket, ringless, horn bypass, 5 terminals, 200 A, 600 VAC, OH/UG service, hub provision only, grounded fifth terminal, service ground lug #14-2 Cu/Al. Wire size range 1/0-350. UL labeled. 16 x 12 x 6 in. Suitable for either top or bottom service cable entry...
Single meter socket, lever bypass, five terminals, 200 A, 600 VAC, OH/UG service. Connections line number 6 to 350 kcmil, load number 6 to 350 kcmil, 3-5/16 hub opening...
Eaton Load Center, 120/240 V, 125 A, Number of Phases: 1, Number of Spaces: 4, Number of Poles: 8, Number of Circuits: 8, Breaker/Load Center Type: Main Lug, Interrupt Rating: 10 kAIC, Cable Size: 14 to 1/0 AWG, Bus Bar Material: Aluminum, Enclosure Type: NEMA 1, Flush Mounting..
Eaton Load Center, 120/240 V, 125 A, Number of Phases: 1, Number of Spaces: 4, Number of Poles: 8, Number of Circuits: 8, Breaker/Load Center Type: Main Lug, Interrupt Rating: 10 kA, Cable Size: 14 to 1/0 AWG, Wiring Configuration: 3-Wire, Bus Bar Material: Aluminum, Enclosure Type: NEMA 1, Surface ..
Eaton Circuit Breaker, Type BR, 120/240 V, 15 A, Number of Phases: 1, Number of Poles: 1, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Instantaneous, Long Time, Wire Size: 14 to 8 AWG, Pigtail Mounting, Dimensions: 6 in L x 3-1/2 in W x 1-1/4 in H, Suitable for: EATON Type B..
Eaton Circuit Breaker, BR, 15 A, Number of Poles: 1, Interrupt Rating: 10 kA, Wire Size: 14/4 AWG, Plug Mounting, Dimensions: 2.9 in L x 2.9 in W x 0.9 in H..
Eaton Circuit Breaker, BR, GFCI, 120/240 VAC, 15 A, Number of Poles: 1, Interrupt Rating: 10 kA, Trip Sensitivity: 15 A, Wire Size: 14 to 8 AWG, Plug Mounting, Dimensions: 4 in L x 3-1/2 in W x 1 in H..
Eaton Circuit Breaker, Type BR, 120/240 V, 20 A, Number of Phases: 1, Number of Poles: 1, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Instantaneous, Long Time, Wire Size: 14 to 8 AWG, Pigtail Mounting, Dimensions: 6 in L x 3-1/2 in W x 1-1/4 in H, Suitable for: EATON Type B..
Eaton Circuit Breaker, GFCI, Type BR, 120/240 VAC, 20 A, Number of Poles: 1, Interrupt Rating: 10 kA, Trip Type: Trip-to-Center, Wire Size: 14 to 8 AWG, Terminal Type: Pigtail, Plug Mounting, Dimensions: 1 in H x 3-1/2 in W x 4 in D..
Eaton Load Center, 120/240 V, 200 A, Number of Phases: 1, Number of Spaces: 12, Number of Poles: 24, Number of Circuits: 24, Breaker/Load Center Type: Main Breaker, Plug-On Neutral, Bus Bar Material: Aluminum, Bus Bar Rating: 200 A, Enclosure Type: NEMA 3R, Flush, Surface Mounting..
Eaton Load Center, 120/240 V, 100 A, Number of Phases: 1, Number of Spaces: 10, Number of Poles: 20, Number of Circuits: 20, Breaker/Load Center Type: Main Breaker, Plug-On Neutral, Cable Size: #4-1/0 AWG, Bus Bar Material: Aluminum, Bus Bar Rating: 100 A, Enclosure Type: NEMA 3R, Flush, Surface Mou..
Eaton Circuit Breaker, Type BR Combination AFCI, 120 V, 15 A, Number of Poles: 1, Interrupt Rating: 10 kAIC, Wire Size: 14 to 8/Aluminum AWG, Plug Mounting, Dimensions: 1.1 in H x 1 in W x 2.56 in D, Suitable for: Type BR Loadcenters..
Eaton Circuit Breaker, AFCI, BR, GFCI, 120 VAC, 15 A, Number of Poles: 1, Interrupt Rating: 10 kA, Wire Size: 14 to 4 AWG, Plug Mounting, Dimensions: 2.9 in L x 2.9 in W x 0.9 in H..
Eaton Circuit Breaker, AFCI, BR, GFCI, 120 VAC, 20 A, Number of Poles: 1, Interrupt Rating: 10 kA, Wire Size: 14 to 4 AWG, Plug Mounting, Dimensions: 2.9 in L x 2.9 in W x 0.9 in H..
Eaton Circuit Breaker, Type BR GFCI, 120/240 V, 20 A, Number of Poles: 1, Interrupt Rating: 10 kAIC, Trip Type: Trip-to-Center, Wire Size: 14 to 8/Aluminum AWG, Number of Spaces: 1, Plug Mounting, Dimensions: 1 in H x 3-1/2 in W x 4 in D..
Eaton Load Center, 120/240 VAC, 100 A, Number of Phases: 1, Number of Spaces: 12, Number of Poles: 24, Number of Circuits: 24, Breaker/Load Center Type: Main Breaker, Plug-On Neutral, Type BR, Interrupt Rating: 10 kAIC, Cable Size: #4 to 1/0 AWG, Wiring Configuration: 3-Wire, Bus Bar Material: Alumi..
Eaton Load Center, 120/240 VAC, 125 A, Number of Phases: 1, Number of Spaces: 12, Number of Poles: 24, Number of Circuits: 24, Breaker/Load Center Type: Main Lug, Plug-On Neutral, Type BR, Interrupt Rating: 10 kAIC, Cable Size: #6 to 2/0 AWG, Wiring Configuration: 3-Wire, Bus Bar Material: Aluminum,..
Eaton Load Center, 120/240 V, 200 A, 1 ph, 12 Spaces, 24 Pole, 24 Circuits, Plug-On Neutral Breaker/Load Center, Bus Bar Material: Aluminum, Bus Bar Rating: 200 A, NEMA 3R Enclosure, Flush, Surface Mounting..
Eaton Load Center, 120/240 VAC, 100 A, Number of Phases: 1, Number of Spaces: 20, Number of Poles: 48, Number of Circuits: 40, Breaker/Load Center Type: Main Breaker, Plug-On Neutral, Type BR, Interrupt Rating: 10 kAIC, Cable Size: #4 to 1/0 AWG, Bus Bar Material: Aluminum, Enclosure Type: NEMA 1, F..
Eaton Indoor Load Center, 120/240 VAC, 200 A, Number of Phases: 1, Number of Spaces: 20, Number of Poles: 40, Number of Circuits: 40, Breaker/Load Center Type: Main Breaker, Interrupt Rating: 25 kA, Wiring Configuration: 3-Wire, Bus Bar Material: Aluminum, Enclosure Type: NEMA 1, Bolt Mounting..
Eaton Load Center, 240 V, 125 A, Number of Spaces: 20, Number of Poles: 1, Number of Circuits: 40, Breaker/Load Center Type: Main Lug, Interrupt Rating: 10 kAIC, Bus Bar Material: Aluminum, Enclosure Type: NEMA 1, Plug Mounting, Metal, Includes: Cover..
Eaton Load Center, 120/240 VAC, 200 A, Number of Phases: 1, Number of Spaces: 30, Number of Poles: 1, Number of Circuits: 60, Breaker/Load Center Type: Main Breaker, Plug-On Neutral, Type BR, Interrupt Rating: 22 kAIC, Cable Size: #6 to 2/0 AWG, Bus Bar Material: Aluminum, Enclosure Type: NEMA 1..
Eaton Load Center, 120/240 VAC, 200 A, Number of Phases: 1, Number of Spaces: 40, Number of Poles: 80, Number of Circuits: 40, Breaker/Load Center Type: Main Breaker, Plug-On Neutral, Type BR, Interrupt Rating: 25 kAIC, Cable Size: #2 to 300 kcmil, Wiring Configuration: 3-Wire, Bus Bar Material: Alu..
Eaton Load Center, 120/240 V, 200 A, 1 ph, 40 Spaces, 80 Circuits, Main Breaker Breaker/Load Center, 25 kA Interrupt, #6 to 2/0 AWG Cable, Bus Bar Material: Aluminum, NEMA 1 Enclosure, Plug Mounting, Metal, Includes: Breakers included: (2) BR120 & (1) BR230..
Eaton Circuit Breaker, AFCI, CH, 120/240 VAC, 15 A, Number of Poles: 1, Interrupt Rating: 10 kA, Pigtail Mounting, Dimensions: 4.5 in L x 0.75 in W x 1.2 in H..
Eaton Circuit Breaker, CH, GFCI, 120/240 VAC, 15 A, Number of Poles: 1, Interrupt Rating: 10 kA, Wire Size: 14 to 6 AWG, Pigtail Mounting, Dimensions: 4-1/2 in L x 3/4 in W x 3-1/4 in H..
Eaton Circuit Breaker, CH, GFCI, 120/240 VAC, 20 A, Number of Poles: 1, Interrupt Rating: 10 kA, Wire Size: 14 to 6 AWG, Pigtail Mounting, Dimensions: 4-1/2 in L x 3/4 in W x 3-1/4 in H..
Eaton Circuit Interrupter, AFCI, Type CH, 120/240 V, 15 A, Number of Poles: 1, Interrupt Rating: 10 kAIC, Trip Type: Common, Plug Mounting, Dimensions: 3.5 in L x 6.1 in W x 1.2 in H..
Eaton Circuit Breaker, CH, GFCI, 120/240 VAC, 15 A, Number of Poles: 1, Interrupt Rating: 10 kA, Wire Size: 14 to 6 AWG, Plug Mounting, Dimensions: 4-1/2 in L x 3/4 in W x 3-1/4 in H..
Eaton Circuit Breaker, AFCI, CH, 120/240 VAC, 20 A, Number of Poles: 1, Interrupt Rating: 10 kA, Plug Mounting, Dimensions: 4-1/2 in L x 3/4 in W x 3-1/4 in H..
Eaton Circuit Breaker, CH, GFCI, 120/240 VAC, 20 A, Number of Poles: 1, Interrupt Rating: 10 kA, Wire Size: 14 to 6 AWG, Plug Mounting, Dimensions: 4-1/2 in L x 3/4 in W x 3-1/4 in H..
A loadcenter is called a breaker box, electrical box or even a fuse box. The main function is to take electricity supplied by the utility and distribute it throughout the home to feed lights and receptacles. Not only does the loadcenter distribute power, it also provides protection...