Heat absorbing metal bead on element link for time delay. Passes motor overload starting currents without needlessly opening. 125 V maximum. Edison base. UL Listed...
Heat absorbing metal bead on element link for time delay. Passes motor overload starting currents without needlessly opening. 125 V maximum. Edison base. UL Listed...
Heat absorbing metal bead on element link for time delay. Passes motor overload starting currents without needlessly opening. 125 V maximum. Edison base. UL Listed...
Heat absorbing metal bead on element link for time delay. Passes motor overload starting currents without needlessly opening. 125 V maximum. Edison base. UL Listed...
Requires 1/2 of one 1 in space. 120 V 10,000 AIC. HACR rated. "L" suffix means breaker attaches to the left hand side of the bus bar only. "R" suffix means breaker attaches to the right hand side of the bus bar only. Breakers should be bought in pairs to fill the 1 in space...
Requires 1/2 of one 1 in space. 120 V 10,000 AIC. HACR rated. "L" suffix means breaker attaches to the left hand side of the bus bar only. "R" suffix means breaker attaches to the right hand side of the bus bar only. Breakers should be bought in pairs to fill the 1 in space...
Requires 1/2 of one 1 in space. 120 V 10,000 AIC. HACR rated. "L" suffix means breaker attaches to the left hand side of the bus bar only. "R" suffix means breaker attaches to the right hand side of the bus bar only. Breakers should be bought in pairs to fill the 1 in space...
Requires 1/2 of one 1 in space. 120 V 10,000 AIC. HACR rated. "L" suffix means breaker attaches to the left hand side of the bus bar only. "R" suffix means breaker attaches to the right hand side of the bus bar only. Breakers should be bought in pairs to fill the 1 in space...
Requires 1/2 of one 1 in space. 120 V 10,000 AIC. HACR rated. "L" suffix means breaker attaches to the left hand side of the bus bar only. "R" suffix means breaker attaches to the right hand side of the bus bar only. Breakers should be bought in pairs to fill the 1 in space...
Quick make, quick break switch, inverse time element tripping operation and trip free handle. Thermal-magnetic trip curve. UL Listed, HACR rated, meets NEMA standards and Federal Specifications, CSA certified. 120/240 volt AC. 10,000 AIR. 3/4" per pole...
Non-interchangeable trip. 120 volt AC; 10,000 AIR. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-TE, Gould, Montgomery Ward and Sears. UL Listed, HACR rated. 15 and 20 amp UL L..
CTL Quadplex breaker with rejection tab, 2-pole outer independent trip and 2-pole center independent trip. Requires (2) 1-inch spaces, Wire size range #14-4, 120/240 volt AC .9lb weight, 3" x 2" x 3". UL Listed, Meets UL 489. Listing for HACR applications. Meets Federal Spec Classification W-C375. 1..
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. ITE/SIEMENS. 120 VAC, 10,000 AIC...
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. ITE/SIEMENS. 120 VAC, 10,000 AIC...
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. ITE/SIEMENS. 120 VAC, 10,000 AIC...
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. Twin single pole, one space per breaker...
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. Twin pole, one space per breaker...
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse type BR and Bryant. ITE/SIEMENS. Requires a 2 in space. 120/240 VAC, 10,000 AIC...
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse type BR and Bryant. ITE/SIEMENS. Requires a 2 in space. 120/240 VAC, 10,000 AIC...
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse type BR and Bryant. ITE/SIEMENS. Requires a 2 in space. 120/240 VAC, 10,000 AIC...
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse type BR and Bryant. ITE/SIEMENS. Requires a 2 in space. 120/240 VAC, 10,000 AIC...
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse type BR and Bryant. ITE/SIEMENS. Requires a 2 in space. 120/240 VAC, 10,000 AIC...