Replacement for Zinsco Q Series. Requires one 3/4 in space. HACR-(heating and air conditioning) rated. Tested and certified in accordance with the National Electric Code and conforms to the ANSI/UL Standard 489, 9th Edition. 120 VAC, 10,000 AIC. Carded...
Replacement for Zinsco R Series. SWD (switch duty) rated. Tested and certified in accordance with the National Electric Code. ETL listed. 10,000 AIC...
Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL Listed. HACR rated. 120/240 volt AC; 10,000 A..
Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL Listed. HACR rated. 120/240 volt AC; 10,000 A..
Quick make, quick break switch, inverse time element tripping operation and trip free handle. Thermal-magnetic trip curve. #14 - 8 wire range 15 to 30 amp, #14 - 2 wire range 40 to 70 amp, #10 - 1/0 wire range 100 amp. UL Listed, HACR rated, meets NEMA standards and federal specifications, CSA certi..
Switching duty rating, duplex type breaker requires 1 in per breaker. Thermal magnetic 40 deg C breakers have rejection tab feature, allows only 42 circuits in the panel in compliance with NEC article 384-15. Interchangeable will replace Bryant, Challenger and Westinghouse. Type BR 120/240 V. 10,000..
Switching duty rating, duplex type breaker requires 1 in per breaker. Thermal magnetic 40 deg C breakers have rejection tab feature, allows only 42 circuits in the panel in compliance with NEC article 384-15. Interchangeable will replace Bryant, Challenger and Westinghouse. Type BR 120/240 V. 10,000..
Switching duty rating, duplex type breaker requires 1 in per breaker. Thermal magnetic 40 deg C breakers have rejection tab feature, allows only 42 circuits in the panel in compliance with NEC article 384-15. Interchangeable will replace Bryant, Challenger and Westinghouse. Type BR 120/240 V. 10,000..
For use in single and 3-phase Type BR load centers 150 A and up. Requires two 1 in pole spaces on left side and two 1 in pole spaces on right side. No BJHDS hold down kit, necessary for using as a main or back feed device, sold separately. #2 to 300 kcmil wire range. 120/240 VAC, 10,000 AIC...
CTL Quadplex breaker with rejection tab, 2-pole outer independent trip and 2-pole center independent trip. Requires two 1 in spaces, Wire size range #14-4, 120/240 VAC.9 lb weight, 3 in x 2 in x 3 in. UL listed, Meets UL 489. Listing for HACR applications. Meets Federal Spec classification W-C375. 1..
CTL Quadplex breaker with rejection tab, 2-pole outer independent trip and 2-pole center independent trip. Requires two 1 in spaces, Wire size range #14-4, 120/240 VAC.9 lb weight, 3 in x 2 in x 3 in. UL listed, Meets UL 489. Listing for HACR applications. Meets Federal Spec classification W-C375. 1..
CTL Quadplex breaker with rejection tab, 2-pole outer independent trip and 2-pole center independent trip. Requires two 1 in spaces, Wire size range #14-4, 120/240 VAC.9 lb weight, 3 in x 2 in x 3 in. UL listed, Meets UL 489. Listing for HACR applications. Meets Federal Spec classification W-C375. 1..
CTL Quadplex breaker with rejection tab, 2-pole outer independent trip and 2-pole center independent trip. Requires two 1 in spaces, Wire size range #14-4, 120/240 VAC.9 lb weight, 3 in x 2 in x 3 in. UL listed, Meets UL 489. Listing for HACR applications. Meets Federal Spec classification W-C375. 1..
CTL Quadplex breaker with rejection tab, 2-pole outer independent trip and 2-pole center independent trip. Requires two 1 in spaces, Wire size range #14-4, 120/240 VAC.9 lb weight, 3 in x 2 in x 3 in. UL listed, Meets UL 489. Listing for HACR applications. Meets Federal Spec classification W-C375. 1..
Cutler-Hammer Circuit Breaker, 120/240 VAC, 20 A, 1 ph, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 8, 14 to 8 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 5 in L x 3 in W x 1 in H, Includes: Captive Line Screw..
Cutler-Hammer Circuit Breaker, 120/240 VAC, 15 A, 1 ph, 2 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 8, 14 to 8 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 5 in L x 3 in W x 2 in H, Includes: Captive Line Screw..
Cutler-Hammer Circuit Breaker, 120/240 VAC, 30 A, 1 ph, 2 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 8, 14 to 8 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 5 in L x 3 in W x 2 in H, Includes: Captive Line Screw..
Eaton's residential BR circuit breakers are used in load centers, panelboards or similar devices. They are made for a wide range of applications and include BR 1 in circuit breakers and accessories for BR-style load centers, arc fault circuit interrupters (AFCI) and ground fault circuit interrupters..
Switching duty rating. Thermal magnetic 40 deg C. Interchangeable, will replace Bryant, Westinghouse and Challenger. Type BR. 120/240 V, 10,000 AIR. 1 in per pole...
Switching duty rating. Thermal magnetic 40 deg C. Interchangeable, will replace Bryant, Westinghouse and Challenger. Type BR. 120/240 V, 10,000 AIR. 1 in per pole...
Switching duty rating. Thermal magnetic 40 deg C. Interchangeable, will replace Bryant, Westinghouse and Challenger. Type BR. 120/240 V, 10,000 AIR. 1 in per pole...
Switching duty rating. Thermal magnetic 40 deg C. Interchangeable, will replace Bryant, Westinghouse and Challenger. Type BR. 120/240 V, 10,000 AIR. 1 in per pole...
Switching duty rating. Thermal magnetic 40 deg C. Interchangeable, will replace Bryant, Westinghouse and Challenger. Type BR. 120/240 V, 10,000 AIR. 1 in per pole...
Cutler-Hammer Circuit Breaker, Type BR, 120/240 V, 100 A, 50/60 Hz Operating Frequency, 1 ph, 2 Pole, 42 kA Interrupt, Quick-Make, Quick-Break Actuator, 4 - 1/0 AWG Wire, Plug Mounting, Dimensions: 6 in L x 4 in W x 2-1/4 in H, 60 to 75 deg C Operating, Suitable for: Protecting the Wires in Home fro..
Cutler-Hammer Circuit Breaker, Type BR, 120/240 V, 100 A, 50/60 Hz Operating Frequency, 1 ph, 2 Pole, 42 kA Interrupt, Quick-Make, Quick-Break Actuator, 4 - 1/0 AWG Wire, Plug Mounting, Dimensions: 6 in L x 4 in W x 2-1/4 in H, 60 to 75 deg C Operating, Suitable for: Protecting the Wires in Home fro..
Cutler-Hammer Circuit Breaker, Type BR, 120/240 V, 60 A, 50/60 Hz Operating Frequency, 1 ph, 2 Pole, 42 kA Interrupt, Quick-Make, Quick-Break Actuator, 8 to 1/0 AWG Wire, Plug Mounting, Dimensions: 2.93 in L x 1.96 in W x 2.92 in H, 60 to 75 deg C Operating..
Cutler-Hammer Circuit Breaker, BR, 120 V, 20 A, 1 ph, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 4 AWG Wire, Plug Mounting, Dimensions: 2.9 in L x 2.9 in W x 0.9 in H..
Cutler-Hammer Circuit Breaker, Type BR, 120 VAC, 20 A, 1 ph, 1 Pole, 10,000 A Interrupt, Instantaneous, Long Time Trip, 14 to 4 AWG Wire, Plug Mounting, Dimensions: 6 in L x 3-1/2 in W x 1-1/8 in H, Suitable for: Type BR Load Center..
Replaces main breaker on 200 A type BR load centers. Includes main breaker, mounting screws, two bus torque nuts and instructions. For field installed mains. #2 to 300 kcmil wire range. 120/240 VAC, 10,000 AIR...
Eaton enclosed breakers offer all the advantages of circuit breakers packed in an enclosure for 240 VAC applications and include a wide range of accessories...
Eaton has enhanced its premium Type CH residential circuit breakers, making the ideal even better. The Type CHF AFCI breakers also include advanced electronics that reduce nuisance tripping and a standard diagnostic LED indicating one of seven trip codes. These features further establish the CH seri..
Eaton has enhanced its premium Type CH residential circuit breakers, making the ideal even better. The Type CHF AFCI breakers also include advanced electronics that reduce nuisance tripping and a standard diagnostic LED indicating one of seven trip codes. These features further establish the CH seri..