Single phase, 2 pole, 2 wire, 240 VAC. Rated 3 hp at 120 V, 10 hp at 240 V. For top and bottom entry and exit, with provision for type H conduit hub. Heavy-duty, high strength, rugged polymer enclosure with UV-resistant features. Swing-up cover remains in place when in open position, protective shie..
Single phase, 2 pole, 2 wire, 240 VAC, non-metallic enclosure. Rated 1-1/2 hp at 120 V, 3 hp at 240 V with time delay fuses (uses class H cartridge fuses, not included). For top and bottom entry and exit, with provision for type H conduit hub. Heavy-duty, high strength, rugged polymer enclosure with..
Air conditioning disconnect, molded case switch looks like a circuit breaker but operates like an ordinary household light switch. 60 A, 2-pole, 240 VAC. Metallic, galvanized steel enclosure, NEMA 3R, rainproof. Packaged for retail sale. Wire size range Cu or Al at 60 or 70 deg C, #14-3. UL listed, ..
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance...
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance...
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance...
Eaton Disconnect Switch, Air Conditioning, Pullout, 120/240 VAC, 60 A, Number of Phases: 1, 3, 10 hp, Number of Poles: 2, Fused: No, Short Circuit Rating: 10 kA, Number of Wires: 2, NEMA Rating: NEMA 3R, Enclosure Material: Steel, Gray, 8.79 in L, 5.4 in W, 3.76 in H..
Steel enclosure. 2-pole, 3-wire, 120/240 VAC, rated 10 hp. Uses cartridge fuses. For central air conditioner. Designed to comply with code requirements for disconnecting means within sight of central air conditioners and heat pumps. Removable closing cap not included. Equipment ground. 14-3 AWG lug ..
Steel enclosure. 2-pole, 3-wire, 240 VAC, rated 10 hp. For central air conditioner. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. 4-3/4 x 7-1/2 x 2 in. UL1429 enclosure pullout switch, UL listed...
Suitable for use as service entrance equipment. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. Designed to comply with code requirements for disconnecting central air conditioners and heat pumps. Open sides and top for quick installation. Impact and corrosion-resistan..
Single phase, 2 pole, 2 wire, 240 V, rated 10 HP, steel enclosure. All lugs positioned for bottom entry and exit wiring. Easy mounting for quick installation. Pullout head can be replaced in off position. 10,000 AIR. 12 - 3 AWG al, 14 - 3 kcmil cu lug wire range. 5-5/32 in x 7-5/16 in x 2-7/32 in. U..
Air conditioning disconnects from Schneider Electric are Underwriters Laboratories® (UL®) Listed NEMA Type 3R rainproof. They are designed to meet all current National Electrical Code® (NEC®) requirements for a disconnecting means on residential and commercial air conditioning installations, as well..