Underground sprinkler system wire. 18/7 solid, 30 V RMS max. Used for sprinkler control systems. Soft annealed solid copper per ASTM B3-90. Polyethylene insulation and jacket. 18 AWG bare copper. Cable consists of 7 bare copper insulated conductors with an overall outer jacket diameter of 0.268 in. ..
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather-resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 deg Celsius to 105 deg C. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class..
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather-resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 deg Celsius to 105 deg C. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class..
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather-resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 deg Celsius to 105 deg C. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class..
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather-resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 deg Celsius to 105 deg C. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class..
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather-resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 deg Celsius to 105 deg C. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class..
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather-resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 deg Celsius to 105 deg C. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class..
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather-resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 deg Celsius to 105 deg C. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class..
For use with outdoor low voltage lighting systems operating at 30 V or less. Put light fixtures where you want or expand a set. UL listed. Made in the USA...
For use with outdoor low voltage lighting systems operating at 30 V or less. Put light fixtures where you want or expand a set. UL listed. Made in the USA...
For use with outdoor low voltage lighting systems operating at 30 V or less. Put light fixtures where you want or expand a set. UL listed. Made in the USA...
Thermoplastic PVC jacketed parallel constructed service cord. Not for hard usage in accordance with NEC. Used for outdoor low voltage lighting systems. Soft annealed stranded cooper per ASTM B3-90 conductor. UL13 approved...
CCI Cable, Low Voltage, 500 ft Length, 2 Conductors, 41/30 Strand, Copper Conductor, PVC Conductor Insulation, PVC Sheath, Black Sheath, 150 V, 18 A, -20 to 60 deg F Operating..
500 ft reel, 18 AWG conductor soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 deg C. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 V. PVC insulation UL13 for power ..
Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 deg C. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 V. PVC insulation UL13 for power limited circu..
Category 5E enhanced data cable with 24 AWG bare copper conductors, polyethylene (non-plenum) insulation and PVC (non-plenum) jacket. Use for gigabit Ethernet, bi-directional transmissions, 100 BaseT, 1000 BaseT, broad band video, fast Ethernet, 155 Mbs ATM, TI, ISDN, 622 Mbps ATM. UL1666, tested to..
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 V maximum. PVC insulation and UL62, UL1581 listed. Spool...
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 V maximum. PVC insulation and UL62, UL1581 listed. Spool...
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 V maximum. PVC insulation and UL62, UL1581 listed. Spool...
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 V maximum. PVC insulation and UL62, UL1581 listed. Spool...
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 V maximum. PVC insulation and UL62, UL1581 listed. Spool...
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 V maximum. PVC insulation and UL62, UL1581 listed. Spool...
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 V maximum. PVC insulation and UL62, UL1581 listed. Spool...
Solid bare copper-covered steel, 22 AWG conductor. Used for CATV, MATV, Class 2 circuits internal wiring, local area networks and RF signal transmission. 100% foil and 40% aluminum braid. Foamed polyethylene insulation and PVC jacket. UL type CL2/CATV, UL style 1354...
Two bare copper conductors laid flat with integral PVC insulation and jacket. Clear jacket construction has one bare copper and one tinned copper conductor. Temperature rated from -20 to 60 deg C, operating voltage 300 V maximum. 18/2 stranded, flat, boxed. UL Standard 13 & 444, CSA C22.2 No. 214, N..
Parallel wire, power limited circuit cable, -20 to 105 deg C. Used for stereos and hi-fi systems, home theater sound systems, lamps and radios. Soft annealed copper per ASTM B3-90 conductor and PVC. UL type CL2, UL1581 and UL13 approved. Clear jacket, on a spool. 250 ft per roll...
Solid and stranded (classes AA and A) bare copper are suitable for overhead transmission and distribution applications. Stranded conductor of greater flexibility (classes B and C) are suitable for uninsulated hook up, jumpers and grounds in electrical construction. Soft drawn copper is Unilay constr..
CCI Work Light with Switch, 120 V, Wattage Rating: 500 W, Lamp Type: Halogen, Number of Lamps: 1, Lumens: 8000 Lumens, Cord Size: 18/3 AWG, Metal, Orange, Dimensions: 14 in H, Includes: Floor Stand with Handle..
CCI Work Light, Wattage Rating: 600 W, Lamp Type: Halogen, Number of Lamps: 3, Lumens: 10,800 Lumens, Cord Size: 18/3 AWG, Metal, Red, Dimensions: 8.2 in L x 5.5 in W x 12.5 in H..
Vinyl outlet lights up to indicate power is on. Solid one-piece clear construction with a single outlet for any 3-conductor extension cord. Use with sump pumps, appliances and power tools. 125 V/15 A/1875 W...
Vinyl outlet lights up to indicate power is on. Solid one-piece clear construction with three outlets. Use with sump pumps, appliances and power tools. 15 A/125 V/1875 W...